Return to site

Nextar Gps Holder

broken image



Site Map

Home | NexStar User's Guide | NexStar Observer List | Downloads | PC/Mac/Tablet/Smartphone Control
Odds and Ends | Firmware Versions | Equip Reviews | Alignment Guides | Manuals | Links

Odds and Ends
NexStar GPS Series

Having problems finding what you are looking for? - Use the Search box above.

Most Commonly Accessed Articles
  • Upgrading the Electronics of NexStar 8/9.25/11 GPS Telescopes - 21 Feb 20
  • GPS-Enabled Scopes Display a Date 20 or 17.5 Years in the Past or Display a Date with a year of '5' after GPS Link - 26 Apr 19
  • Hand Control Compatibility - 25 Feb 12
  • NexStar+ Hand Control - 19 Feb 12
  • Hand Control Version 4 for NexStar GPS, CPC, SLT, GT and 'i' Series - 26 Feb 05
  • Accessories for Your Scope - 15 Jan 19
  • How to Upgrade Hand Control Firmware - 14 Jan 06
  • How to Upgrade Motor Control Firmware - 2 Feb 08
  • Celestron's Online Spare Parts Store - 4 Sep 10
  • Backlash and How to Set Anti-backlash Compensation - 7 Apr 03
  • Power Sources for Your Celestron Scope - 10 Jul 18
  • No Response Errors - 11 Aug 18
  • NexStar GPS Azimuth Motion Rough - Cleaning the Roller Bearings - 26 Jun 20
  • Comparison of NexStar GPS and Meade LX200GPS Scopes - 9 Apr 03
  • Questions about RS-232 Control and Upgrades via PC - 5 Jun 02
  • Common Problems with PC to Scope Communications - 13 Jun 03
Additional Articles
  • Mounting Other OTAs on NexStar Mounts - 29 Jul 20
  • StarGPS-NX GPS Receiver for Celestron Scopes - 18 Mar 19
  • Internal Communications of Celestron Computerized Telescope Mounts - 1 Mar 19
  • Boot Loader Invalid Pkg Errors on NexStar+ Hand Control - 24 Jan 17
  • NexStar GPS Altitude Axis Repair- an article by Tom Hayko - 25 Mar 11
  • SkyScout Connect - Interfacing Your Scope with Celestron's SkyScout - 30 Nov 08
  • Cancel a GoTo in Progress - 18 Jun 07
  • Skyan - Basic Wireless Control of Your Telescope and Motorized Focuser - 7 Jul 06
  • NexStar Hand Control Version 4 User's Guide - Updated Regularly
  • New Upgradeable Hand Control Available from Celestron - 14 Jan 06
  • Celestron Utility for Improved PEC Recordings - PECTool - 25 May 05
  • SCT Corrector Plate Removal - 15 Apr 05
  • Fastar Secondary Turns When Tightening the Retaining Ring - 15 Apr 05
  • Replacing the Battery on the GPS Board - 21 Feb 05
  • Disassembly of the NexStar GPS Azimuth Axis - an article by Lenny Shaffer - 9 Sep 06
  • Disassembly of the NexStar GPS Azimuth Axis - this link takes you to Matthias Bopp's web site, read Adrian Richards' article 'Replace or adjust the azimuth clutch of a NexStar GPS telescope' - 14 Dec 04
  • Disassembly of the NexStar GPS Altitude Axis - this link takes you to Matthias Bopp's web site, read the article 'Replace or adjust the altitude clutch of a NexStar GPS telescope' - 11 Nov 04
  • Some Settings Are Not Reset by Factory Settings Command - 24 Sep 04
  • Doug Robertson's Light Pollution Blocker for NexStar GPS Scopes - 22 Sep 04
  • Ports and Connectors on NexStar GPS Scopes - 27 July 04
  • Cleaning Optics - Part 1 - Glass Surfaces - 22 Mar 04
  • Cleaning Optics - Part 2 - Mirrors - 27 Mar 04
  • Fastar No Longer Offered on NexStar 11 GPS Scopes - 28 Feb 04
  • Updated N11 GPS Motor Control Board from Celestron - Updated 30 Jan 04
  • Collimating Schmidt-Cassegrain Telescopes - 15 Jan 04
  • Extending the Hand Control Cable - 23 Dec 03
  • Get a Full 2' Aperture for Your NexStar 11 - 11 Dec 03
  • Pin Connections in Auto Guide Port - 24 Nov 03
  • Select Alignment Stars - A Program to Aid in Alignment - 8 Sep 03
  • Manual Hand Control for the Auto Guide Port - 31 Jul 03
  • Celestron Now Offering Starbright XLT Enhanced Coatings on SCTs - 30 Jul 03
  • 'No Response 1' Error When Checking Version on N8/9.25/11GPS - 22 Mar 04
  • Celestron Introduces the NexStar 9.25 GPS - 15 May 03
  • Incorrect Date/Time Displayed on GPS Models During Quick Align/Auto Align - 5 Apr 03
  • Creating Index Marks for Hand Control 2.2 - 24 Feb 03
  • Problems Obtaining GPS Link - 24 Dec 02
  • Problems Encountered after Replacement of Motor Control Board in N11 - 14 Nov 02
  • Manual Addendum for Upgraded GPS Hand Control - 27 Jul 02
  • Alternate Locations for the Hand Control - 25 Jul 02
  • First Fastar Lens Assembly for 11' SCTs Available - HyperStar from Starizona - 13 Jul 02
  • Large Replacement Bolts for Your NexStar GPS Tripod - 8 Jul 02
  • Jim Towers' Excellent Battery Tutorial and Guide - 7 Jun 02
  • Correct Installation of the Finderscope - 26 May 02
  • How to Fix Incorrect Local Time on GPS Hand Control - 22 May 02
  • Possible Fixes for Hand Control Misbehavior - 11 May 02
  • Polar Alignment Video for Wedge Mounted Scopes - 5 May 02
  • Warning about Power Limit on the GPS 12V Output Jack - 30 Apr 02
  • Determining the Version on Older NexStar GPS Scopes - 9 Apr 02
  • Make an Accessory Tray for the Heavy Duty Tripod - 23 Feb 02
  • Ease Collimation of the SCT NexStars with Bob's Knobs - 11 Jan 02
  • Prevent your NexStar GPS from Looping Over 360° during Alignment - 11 Jan 02
  • Error in Messier Object in GPS Version 1.2 Hand Control Database - 15 Dec 01
  • Warming the Hand Control to Prevent Sluggish LCD - 17 Dec 01
  • Correcting for Magnetic Declination Error on the GPS Models - 13 Dec 01
  • NexStar Alignment Stars - 2 Dec 07
  • Accurate Centering of Alignment Stars - 22 Aug 01
  • Tripod Improvements - 14 Aug 01
  • Replacing the Power Connector on Your Power Source - 20 Dec 00

Other sources for NexStar information are
the Cloudy Nights Celestron Forum:
www.cloudynights.com
the Yahoo NexStar Group:
groups.yahoo.com/group/NexStar
and the Yahoo NexStarGPS Group:
groups.yahoo.com/group/NexStarGPS


Copyright
Michael Swanson
Contact the webmaster:
swanson.michael@usa.net
  1. Click here to see if your device manufacturer provides free updates for your device, such as software updates, Latest Map Guarantee, free map updates or free extras.
  2. Custom Accessories 23187 Phone/GPS Holder with Dash Pad. For iPod, iPhone, cell phones, mp3 players, GPS and satellite radios Non-slip dash pad securely grips to vehicles dashboard Holder can be.
  3. Shop for nextar q4 gps navigation online at Target. Free shipping on orders of $35+ and save 5% every day with your Target RedCard.
Nextar Gps Holder

Installation

Nextar W3G-01 - GPS navigator overview and full product specs on CNET. Nextar Gps Navigation System free download - System Analyser, Advanced System Optimizer, Google Maps with GPS Tracker, and many more programs.

Included with libindi v1.6+. For Ubuntu it is recommended to install the latest stable version:

sudo apt-add-repository ppa:mutlaqja/ppa
sudo apt-get update && sudo apt-get install libindi

Features

This driver supports Celestron telescopes using the NexStar protocol. The following models use this protocol:

  • NexStar GPS
  • NexStar GPS-SA
  • NexStar iSeries
  • NexStar SE Series
  • NexStar GT
  • Advanced GT
  • CGE mounts
  • CPC
  • SLT
  • CGEM mounts
  • Evolution mounts
  • CGX and CGXL mounts

Really any mount that uses the Celestron Hand Control and connected using the USB or RS232 port on the base of the HC. The driver will operate with NexStar HCs version 4.20 or better, NexStar Plus HCs and StarSense HCs. In all cases it is recommended that the HC is updated to the current version available from Celestron.

Current features of the Celestron NexStar driver:

  • Goto/Slew/Sync
  • Slew rates adjustment
  • Parking
  • Tracking modes: Alt/Az, Eq North, Eq South
  • Time/location setting
  • Pulse guiding
  • Joystick support
  • Hibernate/wakeup (Current NexStar + HC will allow the munt to be power cyceld between hibernate and wake up).
  • Side of Pier (GEM mounts only)
  • Seek home and align (CGX and CGXL mounts only)
  • PEC playback, Record, save and load from file (if the mount supports it).

The driver is based on the NexStar protocol.

For current hand controls the driver will interogate the mount through the HC and set it's capabilities according to the mount type and version read from the mount.

Celestron Focuser Control

The Celestron SCT Focuser can also be controlled using this driver. The focuser must be connected using the AUX cable and a current NexStar Plus HC used. The focuser window will only be shown if the focuser is present. If the focuser is connected via USB, then Celestron SCT driver must be selected as its own standalone focuser driver.

Operation

1. First Time

When using the driver for the first time, ensure to set the telescope's aperture and focal length in the Options tab. Also, set the geographical location and park position in the Site Management tab.

Click the Save button on the Options tab to store these settings.

Go to the Connection tab and select the the serial port the telescope is connected to. Baud rate should be 9600.

Click the Auto search option if you want INDI to search the telescope in all the available serial ports.

The mount must be turned on and aligned. The connection must be made to the connector on the base of the hand control, either a RS232 connection with a USB to RS232 adaptor or a USB connector depending on the HC. The HC to RS232 cable must use the the Celestron cable.

Note: in Debian-based GNU/Linux distributions (like Ubuntu or Mint) the user must belong to the dialout group to be able to use the serial port. Swords and sandals 2 full game.

2. Main Control

Nextar Gps Holder

Installation

Nextar W3G-01 - GPS navigator overview and full product specs on CNET. Nextar Gps Navigation System free download - System Analyser, Advanced System Optimizer, Google Maps with GPS Tracker, and many more programs.

Included with libindi v1.6+. For Ubuntu it is recommended to install the latest stable version:

sudo apt-add-repository ppa:mutlaqja/ppa
sudo apt-get update && sudo apt-get install libindi

Features

This driver supports Celestron telescopes using the NexStar protocol. The following models use this protocol:

  • NexStar GPS
  • NexStar GPS-SA
  • NexStar iSeries
  • NexStar SE Series
  • NexStar GT
  • Advanced GT
  • CGE mounts
  • CPC
  • SLT
  • CGEM mounts
  • Evolution mounts
  • CGX and CGXL mounts

Really any mount that uses the Celestron Hand Control and connected using the USB or RS232 port on the base of the HC. The driver will operate with NexStar HCs version 4.20 or better, NexStar Plus HCs and StarSense HCs. In all cases it is recommended that the HC is updated to the current version available from Celestron.

Current features of the Celestron NexStar driver:

  • Goto/Slew/Sync
  • Slew rates adjustment
  • Parking
  • Tracking modes: Alt/Az, Eq North, Eq South
  • Time/location setting
  • Pulse guiding
  • Joystick support
  • Hibernate/wakeup (Current NexStar + HC will allow the munt to be power cyceld between hibernate and wake up).
  • Side of Pier (GEM mounts only)
  • Seek home and align (CGX and CGXL mounts only)
  • PEC playback, Record, save and load from file (if the mount supports it).

The driver is based on the NexStar protocol.

For current hand controls the driver will interogate the mount through the HC and set it's capabilities according to the mount type and version read from the mount.

Celestron Focuser Control

The Celestron SCT Focuser can also be controlled using this driver. The focuser must be connected using the AUX cable and a current NexStar Plus HC used. The focuser window will only be shown if the focuser is present. If the focuser is connected via USB, then Celestron SCT driver must be selected as its own standalone focuser driver.

Operation

1. First Time

When using the driver for the first time, ensure to set the telescope's aperture and focal length in the Options tab. Also, set the geographical location and park position in the Site Management tab.

Click the Save button on the Options tab to store these settings.

Go to the Connection tab and select the the serial port the telescope is connected to. Baud rate should be 9600.

Click the Auto search option if you want INDI to search the telescope in all the available serial ports.

The mount must be turned on and aligned. The connection must be made to the connector on the base of the hand control, either a RS232 connection with a USB to RS232 adaptor or a USB connector depending on the HC. The HC to RS232 cable must use the the Celestron cable.

Note: in Debian-based GNU/Linux distributions (like Ubuntu or Mint) the user must belong to the dialout group to be able to use the serial port. Swords and sandals 2 full game.

2. Main Control

The Connection field allows you to connect and disconnect the mount according to the options indicated in the Connection tab.

On Set button allows you to select the action that must be executed when the Set button in the Eq. Coordinates fields is pressed. Three options
are available:

  • Track: the telescope will slew to the target location and then engage tracking using the tracking mode selected in the Track Mode field.
  • Slew: the telescope will not start tracking after reaching the target.
  • Sync: Update the telescope coordinates without moving the motors.

The Abort Motion button can be used to stop the mount at any time.

Tracking can be engaged and disengaged by pressing the On/Off buttons in the Tracking property.

Mount parking and unparking is controlled by the Parking property.

The Use Pulse Cmd property can be enabled to guide the mount through the communications interface and eliminates the requirement of using an ST-4 cable to guide the mount.

Most of the functions of this panel are available through the contextual menu shown by clicking the left mouse button in the KStars sky map, so the user don't need to enter the target coordinates manually.

Nextar Gps Holder Cell Phone Holder

3. Options

The Options tab is used to set debugging and other configuration options, as well as being able to load and save configurations.

  • Polling period: The INDI driver reads values from the mount periodically. The reading period in milliseconds can be changed using this field.
  • Debug: Enable debug logging where verbose messages can be logged either directly in the client or a file. If Debug is enabled, advanced properties
    are created to select how to direct debug output. Watch a video on how to submit logs.
  • Simulation: Enable to disable simulation mode for testing purposes.
  • Configuration: Load or save the driver settings to a file. Click default
    to restore default settings that were shipped with the driver.
  • Scope Properties: Enter the Primary and Seconday scope information. Up to six different configurations for Primary and Secondary Guider telescopes can be saved separately, each with an optional unique label in Scope Name property.
  • Hibernate: Enable or disable mount hibernation.
  • Scope Config: Select the active scope configuration.
  • Joystick: Enable or Disable joystick support. An INDI Joystick driver must be running for this function to work. For more details, check the
    INDI Telescope Joystick tutorial.

4. Motion Control

This panel allows you to manually control the movement of the telescope. Button labels here are self-explanatory.

4a. PEC

If your mount supports PEC then the PEC management options are shown in the Motion Control Tab. PEC is available on most GEM mounts and the higher end fork mounts but only when operated on a wedge. These PEC options will only be shown if your mount supports PEC.

  • PEC Control:
    • Seek Index - This will move the mount by up to tywo degrees in Ra to find the PEC index. This is essential to allow PEC Playback or record. The PEC State changes to Index Found and the PEc Index will show the current value when this is done.
    • Stop - this will stop either a PEC playback or record. The PEC State changes to Index Found. If stop is pressed before a PEC Record has completed no data is saved.
    • Playback - PEC playback is started. The PEC State will change to PEC Playback. This will continue until Stop is pressed. If a slew is done when PEC Playback is active then it will remain active.
    • Record - The PEC Record process is started. This will continue until a full PEC record cycle is completed, recording will then stop and the current PEC data is saved to a file. The file name is shown in the Load PEC - File Name text box.
      The record process is:
      • Seek PEC Index
      • Start guiding
      • Start PEC recording
      • Wait until it has completed.
      • Further PEC records can be done, collecting multiple PEC record cycles and averaging than can produce a better PEC record.
  • PEC Info - two text information boxes are shown:
    • PEC State - This shows the current PEC state. These are:
      • Available - the mount supports PEC but the index has not been found. The only option is to press Seek Index to seek the PEC index.
      • Index Found - The PEC index has been found, Playback or Record can be started.
      • PEC Playback - the mount is playiing back it's current PEC data, it will continue unti Stop is pressed.
      • PEC Recording - the mount is recording PEC data using the current guide corrections. This will continue for a full PEC cycle, currently 8 minutes.
      • There are two other states - Unknown and not available. These should not be visible because none of the PEC properties will be enabled unless PEC is possible.
    • PEC Index - this shows the current PEC index. It is currently a value from 0 to 88 which is read from the mount. This increments as the PEC index changes, currently about every 8 seconds.
  • Load PEC - this has one text box - File Name. This shows the file name in which the last PEC record was saved. The text box ca be edited and pressing the Set button will load the PEC data in the current file to the mount.

For simple use just record a single PEC run. This will be saved in the mount and can be used by selecting Playback.

For more advanced use record multiple PEC runs and average the PEC data. The earlier mounts benefit from multiples of three recording runs taken consecutively. This is because some gears will repeat over three PEC cycles and averaging 3 cycles will remove this effect. Once the new file is produced it can be loaded by specifying its file name in the File Name text box and pressing Set to load it to the mount.

There is no way included to average the PEC data but this can be done in a spreadsheet by loading multiple PEC runs, averaging the data and writing the result to a new PEC data file. Or someone could write a PEC management tool..

The PEC data format is the same as the one used in Celestron's PECTool application, the data is saved as one number per line as follows:
Line 1: Number of PEC bins, currently alway 88
Lines 2 to 90: 89 PEC values, the first one is always zero and they are the sum of the PEC corrections to date. There is one more than the number of bins.
Line 91: The number of arc seconds of Ra movement for one PEC cycle, currently 7200.

Run This Town ft. Rihanna & Kanye West) by Jay-Z - Blueprint 3, Hip Hop music from Atlanta, GA on ReverbNation. Or $1.29 to buy MP3. Run This Town feat. Rihanna & Kanye West by Jay-Z. 4.1 out of 5 stars 38. MP3 Music Listen with Music Unlimited. Run This Town feat. Rihanna & Kanye West Explicit by Jay-Z. 4.1 out of 5 stars 38. MP3 Music Listen with Music Unlimited. Listen to Singer's Edge Karaoke Run This Town (Originally Performed By Jay-Z & Rihanna & Kanye West) Instrumental Version MP3 song. Run This Town (Originally Performed By Jay-Z & Rihanna & Kanye West) Instrumental Version song from the album Run This Town (Originally Performed By Jay-Z & Rihanna & Kanye West) Karaoke Version is released on Jun 2015. Rude Boy (DJ Mhark Quick Kutz) Clean feat DJ Mhark: 3:08. Run This Town (Dj Allan MMP Quick Hitter) (Dirty) feat Jay - Z, Kanye West. Rihanna — Background Run This Town Mashup: Reviews. No reviews for this album. Create review for Background Run This Town Mashup. Your name: Review Title: Rate: Review text.

It's possible that Celestron will increase the number of PEC bins on later mounts, the current implementation should be OK up to 190 bins. Command and conquer frostbite 2 download utorrent.

5. Site Management

Time, Location, and Park settings are configured in the Site Management tab.

UTC: UTC time and offsets must be set for proper operation of the driver upon connection. The UTC offset is in hours. East is positive and west is negative.

Nextar Gps Holder Replacement

Location: Latitude and longitude must be set for proper operation of the driver upon connection. The longitude range is 0 to 360 degrees increasing eastward from Greenwich.

Parking: By default, the parking position is at the celestial pole. To restore parking position to its default value, click the Default button under Park Options.
You can set a custom parking position using two methods:

  • Enter the desired AZ & ALT values for the custom parking position.
  • Slew the mount to the desired parking position, then press Current.

Press Write Data to save the new parking position.

The mount must be unparked before you can set a new parking position.

You can park the telescope by clicking on Park on the Main Control tab. If the telescope is already parked, click the Unpark button to unpark it. You cannot perform any motion unless the telescope is first unparked.

6. Guide

Guide N/S/W/E: Guiding pulses durations in milliseconds. This properties are meant for guider application (e.g. PHD2) and not intended to be used
directly.

7.Focus

The min position and max position are read from the focuser. They are set by using the Celestron focuser calibration. If they are both zero this is an indication that the focuser has not been calibrated. The focuser cannot be moved unless it has been calibrated. This is to protect the focuser from running into the hard stops and causing damage.

Issues